Hunza Cable – 8 Core RGBW
For LuxrR Integral RGBW products, this cable set features both positive and negative RGBW conductors.
Available for customization to any desired length.
Construction & Material:
| Conductor | Size: 22AWG or 0.65mm Material: Bare Copper |
| Jacket | Material: PVCMin Thickness: 0.69mmDiameter: Ø7.30mm (±0.20mm)Colours: Black, Semi-MattJacketMarking: E23326 AWM STYLE 285522AWG VW-1 60°C 30V AWM I/II A 60°C 30VFT1 LF EVERLONG |
| Insulation |
Material: 0.2mm Diameter: PVC Min Thickness: Ø7.30mm (±0.20mm) Colours: E23326 AWM STYLE 2855 22AWG VW-1 60°C 30V AWM I/II A 60°C 30V FT1 LF EVERLONG |
Electrical & Physical Properties:
| Conductor Resistance | 55.4 /KM (MAX) @ 20°C |
| Insulation Resistance | 0.75 M/KM (MIN) @ 20°C/DC 500V |
| Dielectric Withstand | 500 VAC/MIN (No Breaking) |
| Flame Test | FT1, VW-1 (PASS) |
| Heat Shock Test | 121±1°C/1hr ( No Cracking) |
| Heat Bend Test | -10±2°C/4hr ( No Cracking) |
| Temparature Resistance | 85°C |
| Insulation | Jacket | ||
|
UN-AGED |
Tensile Strength (CONTROL) | 2400 PSI (MIN) | 1500 PSI (MIN) |
| Elongation | 300% (MIN) | 100% (min) | |
|
AGED |
Tensile Strength | 75% (MIN) | 70% (min) |
| Elongation | 75% (MIN) | 65% (min) | |
| Deformation Test | Max 50% |
Management Standards for Environment-related Substance: EL-008-00